Installa�On Of The Gearmotor; Installing On Gates Without Rack - Accessmatic Dogo 1224 Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

d
ogo
1224
Opening your life
3.3.1 Installa�on of the Gearmotor
The Dogo 1224 can be installed in two situa�ons:
1). Installing on gates without rack; in this condi�on must be installed first, followed by PRK-1 rack.
2). Installing on a gate with rack; in this condi�on must be connected to the exis�ng rack.

3.3.1.1 Installing on Gates without Rack

1). Dig the founda�ons based on "Prepara�on for Motor Installa�on" and please no�ce the distances indicated in Figure 12.
2). Lay the conduits for the power cables and leave 30-50 cm longer as Figure 17.
3). Fit the two bent bins (as below "A" part in Figure 18) into the founda�on and fix them above and below with two nuts
(as below "B" part in Figure 18); make sure the outstanding part does not exceed the maximum height as Figure 18.
4). Put the founda�on plate and make sure the gate keeping the distances shown as Figure 12.
5). Fit the conduits through the hole of the founda�on plate.
6). Pour the concrete.
7). Sink the plate into the concrete and make sure it is parallel to the leaf.
8). A�er the concrete is dry enough, remove the two upper nuts form the plate and cut the cable conduits above the plate
if the conduits are too long.
9). Remove the two caps beside the le� and right sides of the gearmotor as shown in Figure 19.
10). Put gearmotor on the plate and then screw the two nuts and washers as Figure 20.
www.accessmatic.com