Guía rápida
[12] [1612] Motor Voltage
(Tensión del motor)
[13] [1613] Frequency
(Frecuencia)
[14] [1614] Motor Current
(Intensidad motor)
[15] [1615] Frequency [%]
(Frecuencia [%])
[16] [1618] Motor Thermal
(Térmico del motor)
[17] [1630] DC Link Voltage
(Tensión del enlace de CC)
[18] [1634] Heatsink Temp.
(Temp. disipador térmico)
[19] [1635] Inverter Thermal
(Térmico inversor)
[20] [1638] SL Controller State
(Estado controlador SL)
[21] [1650] External Reference
(Referencia externa)
[22] [1651] Pulse Reference
(Referencia de pulsos)
[23] [1652] Feedback [Unit]
(Realimentación [unidad])
[24] [1660] Digital Input
18,19,27,33 (Entrada digital
18,19,27 y 33)
[25] [1661] Digtial Input 29
(Entrada digital 29)
[26] [1662] Analog Input 53 (V)
(Entrada analógica 53 [V])
[27] [1663] Analog Input 53 (mA)
(Entrada analógica 53 [mA])
[28] [1664] Analog Input 60
(Entrada analógica 60)
[29] [1665] Analog Output 42
[mA] (Salida analógica 42 [mA])
[30] [1668] Freq. Input 33 [Hz]
(Entrada de frecuencia 33 [Hz])
[31] [1671] Relay Output [bin]
(Salida de relé [bin])
[32] [1672] Counter A (Contador
A)
[33] [1673] Counter B (Contador
B)
[34] [1690] Alarm Word (Código
de alarma)
[35] [1692] Warning Word
(Código de advertencia)
[36] [1694] Ext. Status Word
(Código de estado ampliado)
8-5* Digital/Bus
8-50 Coasting Select (Selección
inercia)
[0] DigitalInput (Entrada digital)
[1] Bus
[2] Logic And (Y lógico)
*[3] Logic Or (O lógico)
MG02BB4P
Quick Guide●Kurzanleitung●Guide rapide●Guía rápida●Guia Rápido●Краткое
руководство
8-51 Quick Stop Select
(Selección parada rápida)
Vea el par. 8-50 * [3] Logic Or (O
lógico)
8-52 DC Brake Select (Selección
freno CC)
Consulte el par. 8-50 *[3] Logic
Or (O lógico)
8-53 Start Select (Selec.
arranque)
Consulte el par. 8-50 *[3] Logic
Or (O lógico)
8-54 Start Select (Selec. sentido
inverso)
Consulte el par. 8-50 *[3] Logic
Or (O lógico)
8-55 Set-up Select (Selec. ajuste)
Consulte el par. 8-50 *[3] Logic
Or (O lógico)
8-56 Preset Reference Select
(Selec. referencia interna)
Consultar el parámetro 8-50 *[3]
Logic Or (O lógico) 8-8* Bus
communication Diagnostics
(Diagnóstico de comunicación
por bus)
8-80 Bus Message Count
(Recuento de mensajes por bus)
0-0 N/A *0 N/A
8-81 Bus Error Count (Contador
errores de bus)
0-0 N/A *0 N/A
8-82 Slave Messages Rcvd
(Mensajes de esclavo recibidos)
0-0 N/A *0 N/A
8-83 Slave Error Count
(Contador errores de esclavo)
0-0 N/A *0 N/A
8-9* Bus Jog / Feedback
(Velocidad fija / Realimentación)
8-94 Bus feedback 1 (Realimen-
tación de bus 1)
0×8000-0×7FFF *0
13-** Smart Logic
13-0* SLC Settings (Ajustes SLC)
13-00 SL Controller Mode
(Modo Controlador SL)
*[0] Off (Desactivado)
[1] On (Sí)
13-01 Start Event (Evento
arranque)
[0] False (Falso)
[1] True (Verdadero)
[2] Running (Funcionamiento)
[3] InRange (En intervalo)
[4] OnReference (En referencia)
[7] OutOfCurrentRange (Fuera
ran. intensidad)
Danfoss A/S © 05/2016 All rights reserved.
[8] BelowILow (I Posterior baja)
[9] AboveIHigh (I Anterior alta)
[16] ThermalWarning
(Advertencia térmica)
[17] MainOutOfRange (Tens. alim.
fuera ran.)
[18] Reversing (Cambio de
sentido)
[19] Warning (Advertencia)
[20] Alarm_Trip (Descon._alarma)
[21] Alarm_TripLock
(Alarma_bloq. descon.)
[22-25] Comparator 0-3
(Comparador 0-3)
[26-29] LogicRule0-3 (Regla lógica
0-3)
[33] DigitalInput_18 (Entrada-
Digital_18)
[34] DigitalInput_19 (Entrada-
Digital_19)
[35] DigitalInput_27 (Entrada-
Digital_27)
[36] DigitalInput_29 (Entrada-
Digital_29)
[38] DigitalInput_33 (Entrada-
Digital_33)
*[39] StartCommand (Comando
de arranque)
[40] DriveStopped (Convert. frec.
parado)
13-02 Stop Event (Evento
parada)
Consultar el parámetro 13-01 *
[40] DriveStopped (Convertidor
parado)
13-03 Reset SLC (Reiniciar SLC)
*[0] Do not reset (No reiniciar)
[1] Reset SLC (Reiniciar SLC)
13-1* Comparators
(Comparadores)
13-10 Comparator Operand
(Operando comparador)
*[0] Disabled (Desactivado)
[1] Reference (Referencia)
[2] Feedback (Realimentación)
[3] MotorSpeed (Veloc. motor)
[4] MotorCurrent (Intensidad
motor)
[6] MotorPower (Potencia del
motor)
[7] MotorVoltage (Tensión del
motor)
[8] DCLinkVoltage (Tensión del
bus CC)
[12] AnalogInput53 (Entr. analóg.
53)
[13] AnalogInput60 (Entr. analóg.
60)
[18] PulseInput33 (Entrada pulsos
33)
[20] AlarmNumber (Número de
alarma)
[30] CounterA (Contador A)
[31] CounterB (Contador B)
13-11 Comparator Operator
(Operador comparador)
[0] Less Than (Menor que)
*[1] Approximately equals
(Aproximadamente igual)
[2] Greater Than (Mayor que)
13-12 Comparator Value (Valor
comparador)
-9999-9999 *0,0
13-2* Timers (Temporizadores)
13-20 SL Controller Timer
(Temporizador del controlador)
0,0-3600 s *0,0 s
13-4* Logic Rules (Reglas lógicas)
13-40 Logic Rule Boolean 1
(Regla lógica booleana 1)
Consulte el par. 13-01 * [0] False
(Falso)
[30] - [32] SL Time-out 0-2
(Tiempo límite SL 0-2)
13-41 Logic Rule Operator 1
(Operador regla lógica 1)
*[0] Disabled (Desactivado)
[1] And (Y)
[2] Or (O)
[3] And not (Y NO)
[4] Or not (O NO)
[5] Not and (NO Y)
[6] Not or (NO O)
[7] Not and not (NO Y NO)
[8] Not or not (NO O NO)
13-42 Logic Rule Boolean 2
(Regla lógica booleana 2)
Véase par. 13-40 * [0] False
(Falso)
13-43 Logic Rule Operator 2
(Operador regla lógica 2)
Consulte par. 13-41 *[0] Disabled
(Desactivado)
13-44 Logic Rule Boolean 3
(Regla lógica booleana 3)
Consulte par. 13-40 * [0] False
(Falso)
13-5* States (Estados)
13-51 SL Controller Event
(Evento Controlador SL)
Consulte el par. 13-40 * [0] False
(Falso)
13-52 SL Controller Action
(Acción Controlador SL)
*[0] Disabled (Desactivado)
[1] NoAction (Sin acción)
95
4
4