Pulse Output Function Module; Combined Function Module (In/Out) - Diehl Metering Sharky 775 Instrucciones De Montaje

Ocultar thumbs Ver también para Sharky 775:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English

7.4 Pulse output function module

The module is equipped with 2 pulse outputs, which can be freely pro-
grammed using the IZAR@SET software. The outputs are indicated as
"O1 - " and "O2 - " on the terminal strip and as Out1 and Out2 in the
display.
ƒ
external supply:
Vcc = 3-30 VDC
ƒ
output current ≤ 20 mA
with a residual voltage of
≤ 0.5 V
ƒ
open collector (drain)
ƒ
electrically insulated
ƒ
Output 1: f ≤ 4Hz
Pulse duration:
125 ms ± 10 %
pulse pause:
≥ 125 ms – 10 %
ƒ
Output 2: f ≤ 100 Hz
pulse duration/pulse
pause~1:1
ƒ
The volume pulse weight-
ing can be freely pro-
grammed
ƒ
standard: last digit in the
display

7.5 Combined function module (IN/OUT)

The combined module has 2 inputs and 1 output.
See chapter 7.3 for the specific
characteristics on the pulse
input.
The pulse output is specified
as pulse output 1 under point
7.4, not however galvanically
isolated.
Energy
external
meter
Pulse
output
module
V
CC
Pulse
GND
-29-
Tabla de contenido
loading

Tabla de contenido