03. User can set local address, baud rate and data format of the inverter
through auxiliary device keypad.
04. Auxiliary device report current failure information to mainframe in the last
response frame.
05. TDS600 provides RS485 interface.
2.3. Transport mode
Asynchronous serial, semiduplex transport mode. Default format and transport
rate: 8-N-1, 9600bps.For specific parameter setting please see description for
F05 group function code.
(remark: The definition for this parameter is only effective under free –port
communication mode, and definition for other parameters are the same as
original)
F05.00
Protocol selection
F05.01
Baud rate
configuration
Appendix A Free-port Communication Protocol
0:Modbus protocol
1:reserved
2:Profibus protocol(extension effective)
3:CanLink protocol(extension effective)
4:CANopen protocol(extension effective)
5:freedom protocol 1(can modify all function
parameters of TDS600)
6:freedom protocol 2 (can only modify part of function
parameter of TDS600)
Remark: expansion card is needed if select protocol
2, 3, 4
LED first bit:freedom protocol and Modbus baud rate
selection
0:300BPS
1:600BPS
2:1200BPS
3:2400BPS
4:4800BPS
5:9600BPS
6:19200BPS
7:38400BPS
8:57600BPS