Fault
When the cleaner is switched
on the motor buzzes without
starting
The motor switches off
When a cleaning agent injector
(optional accessory) is used,
cleaning agent is not supplied
40
Cause
> The mains voltage is too low
or there is a phase failure.
> The pump is blocked or
frozen
> Incorrect cross-section or
length of the extension lead
> The switch is in position 'M'
and the cleaner has not
been used for more than 5
minutes
> The overload protection has
been activated due to
overheating or overloading
of the motor
> High-pressure nozzle is dirty
> Injector is dirty or suction
hose is blocked
> Cleaning agent tank is
empty
> The twist grip on the spray
pipe is not set to low
pressure
Remedy
Have the electrical
connection checked
Contact the Alto customer
service
Use lead with correct cross-
section or length
Operate the main switch
again
Check that the mains voltage
and the cleaner voltage are
the same. Switch off the
cleaner and allow it to cool
for at least 3 minutes
Change the high-pressure
nozzle
Clean
Fill the cleaning agent tank
Turn the twist grip on the
spray pipe anti-clockwise as
far as possible