Alto POSEIDON 1200 Instrucciones De Manejo página 39

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 303
8 Troubleshooting
Fault
Pressure drop
Pressure fluctuations
The motor does not start when
the cleaner is switched on
Cause
> Air in the system
> High-pressure nozzle
blocked/worn
> Pressure control on the
spray pipe is not set
correctly.
> Pump draws in air (only
possible in suction mode)
> Lack of water
> Water inlet hose is too long
or its cross-section too small
> Lack of water caused by
blocked water filter
> Lack of water because max.
permissible suction height
has not been heeded
> The plug is not inserted
properly, i.e. there is no
current
> The mains fuse is switched
off
Remedy
Vent the system by operating
the spray gun several times
at short intervals. If
necessary, operate the
cleaner for a short time
without the high-pressure
hose connected
Clean/replace the high-
pressure nozzle
Set the required working
pressure
Check that the suction set is
air-tight
Open the tap
Use specified water inlet
hose
Clean the water filter in the
water connection (never
work without water filter)
See instructions
Check the plug, lead and
switch and if necessary have
them replaced by a trained
electrician
Switch on the mains fuse
39
loading

Este manual también es adecuado para:

Poseidon 1280