Install Outdoor Unit; Air Purging And Leakage Test; Electric Wiring - Premium PAC9039G Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Install outdoor unit

1.
Disassemble the handle on the outdoor unit right side plate.
2.
Take off cord anchorage. Connect and fix power connect
cord (for cooling and heating unit,connect and fix power
connect cord and signal control wire)to terminal block.
3.
Fix the power connection cable with cord anchorage,
(for cooling and heating unit, use the cord anchorage
to fix the power connection cable and the signal
control wire).
4.
Ensure wire has been fixed well.
5.
Install the handle.
NOTE:
Wrong wiring may cause spare parts malfunction.
After the cable fixed, make sure there should be
a free space between the connection and
connection and fixing place on the lead wire.
1. Connect charging hose of manifold valve to charge end of low pressure
valve (both high/low pressure valves must be tightly shut).
2. Connect joint of charging hose to vacuum pump.
3. Fully open handle handle of Lo manifold valve.
4. Open the vacuum pump to evacuate. At the beginning, slightly
loosen joint nut of low pressure valve to check if there
is air coming inside. (If noise of vacuum pump has
been changed, the reading of multimeter is 0) Then
tighten the nut.
5. Keep evacuating for more than 15mins and make
sure the reading of multi-meter is
(-76cmHg) . .
6. Fully open high/low pressure valves.
7. Remove charging hose from charging end of low pressure valve.
8. Tighten bonnet of low-pressure valve. (As shown in Fig.10)
Condensate drainage of outdoor unit (no for cooling only)
The condensate and defrosting water formd during heating
in the outdoor unit can be properly discharged by drainage
pipe .
Installation method:set the drain connection in
chassis has been installed and then connect drainage pipe
with drain nozzle,so that condensate and defrosting waer can
be properly discharged

Electric wiring

Air purging and leakage test

-1.0
10 pa
Handle
05、
blue black
24K Cool only type:
blue black brown
Multimeter
-76cmHg
Lo Handle
Charging hose
5
Ø
25 hole of the
20
05 、
07
07
09
12K、
Heat pump type and
14K、18K
GWH18NC-D3NNC7A
Cool only type:
N(1) 2
N(1)
2
blue black violet orange
yellow-
yellow-green
green
Indoor unit
connection
18K Heat pump type:
N(1) 2
blue black violet orange
Indoor unit
connection
N(1)
2
3
24K Heat pump type:
N(1) 2
yellow-green
blue black brown violet
Indoor unit
connection
Indoor unit
connection
Manifold
Valve
Manometer
Hi handle
Charging hose
Low pressure valve
Fig.10
Chassis
Drain
connection
09
12K
4
5
Indoor unit
connection
4
5
yellow-
green
3
4
5
orange
yellow-
green
Vacuum pump

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Pac12519gPac13039gPac18039gPac24039g

Tabla de contenido