Pentair STA-RITE Guía Del Usuario Y De Instalación página 8

Filtro de arena de montaje superior
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4
10. Tighten clamp screws firmly and visually check the valve tank and
clamp assembly to insure that the joint is correctly assembled.
11. The filter unit has a maximum operating pressure listed on the
filter name plate. DO NOT OPERATE this unit above the maximum
operating pressure of the valve or the filter. Never connect the
filter and valve unit to a pump which can generate a pressure that
exceeds the operating pressure of the filter or valve.
12. Use sealant on all tapered male connections of pipes and fittings.
Use only sealant compounds suited for plastic pipe. Support
pipe to prevent strains on filter, pump or valve. DO NOT USE
PETROLEUM BASED PRODUCTS. NOTICE: All valve internal
threads are tapered except the air bleeder connection. Do not over
tighten tapered thread connections.
13. Install pressure gauge in 1/4"NPT port directly across from the
pump port of the valve.
14. Never store pool chemicals within ten (10) feet of your pool filter,
pump or valve. Pool chemicals should always be stored in a cool,
dry, well ventilated area.
filter, pump or valve attachments to separate and could cause serious bodily injury or property
damage.
wired and plumbed, this pump will operate in a safe manner.
681-31 of the NEC requires that a GFCI be used if this pump is used with a storable pool.
15. Avoid over tightening the pipe threads when connecting fittings
to the pump or valve. Proper procedure is to apply a pipe sealant
to the thread and then install hand tight plus one turn. DO NOT
OVER TIGHTEN.
SAND DOLLAR
and CRISTAL-FLO™ II Top Mount Sand Filter Installation and User's Guide
®
High Pressure:
Improper tank valve assembly could cause the valve to separate
and cause serious injury and/or major property damage.
Chemical fumes and/or spills can cause serious corrosion to the filter and
pump structural components. Structurally weakened components can cause
The system's centrifugal pump operates with electrical voltage, and can
generate both vacuum and pressure in the water system. When properly
High voltage can cause serious or fatal injury. Always install a suitable
GFCI at the power source of this unit as an added safety precaution. Article
Tabla de contenido
loading

Este manual también es adecuado para:

Sand dollarCristal-flo iiCristal-flo

Tabla de contenido