Always remove the battery before carrying out any work on the power tool.
Condition
Machine cuts out during operation
Running time is too short
Battery jams when being inserted in power
tool / charger
Battery is not being charged even though
LED on charger glows green
Light emitting diode on charger flashes red
1)
STIHL recommends a STIHL servicing dealer.
BGA 85
Cause
Battery or machine's electronics too warm Take battery out of machine, allow bat -
Electrical or electromagnetic fault
Battery not fully charged
Useful life of battery has been reached or
exceeded
Guides / contacts dirty
Battery too hot / too cold
(1 light emitting diode on battery glows red)
No electrical contact between charger and
battery
Fault in battery
(4 light emitting diodes on battery flash red
for about 5 seconds)
Fault in charger
Remedy
tery and machine to cool down
Remove the battery and refit it
Charge the battery
1)
Check battery
and replace
Carefully clean the guides / contacts
Allow battery to cool down / allow battery
to warm up slowly at temperature of
about 15°C - 20°C
Operate charger only in closed, dry
rooms at ambient temperatures between
+5°C and +40°C
Remove the battery and refit it
Take the battery out of the power tool
and refit it. Switch on the machine – if the
LEDs continue to flash, the battery is
faulty and must be replaced.
Have charger checked by servicing
1)
dealer