Installation
3. Installation
3.1 Installing the pouch with glass cleaner
•
Take a new pouch out of the box and screw off the protective cap.
•
Open the compartment on handheld unit by sliding the black button back and
remove the lid (picture 1).
•
Push the pouch onto the connector at the top of the compartment. You can
rotate the connection stem up to have better access. (picture 2) Always change
the pouch with the with the cleaning head facing up.
•
Push the pouch as far as possible on the connection stem to prevent leakage.
(picture 3)
•
Push the pouch and pin down so that it fits into the compartment.
•
Replace the lid and confirm that the black button is locked in place (picture 4)
Attention: Always change the pouch by holding the system with cleaning head
•
up. Pull the pouch down, so you prevent leackage in this compartment. Clean
and dry possible spills with a clean cloth.
3.2 Assembly of the TriPad
•
The system is equipped with a triangle shaped microfibre pad.
•
The TriPad provides maximum cleaning power in combination with the Stingray
Glass Cleaner.
•
Just put the Microfibre Tri Pad onto the padholder. Fix it in place with the
elastic straps in each corner.
•
Once the TriPad is dirty, just take it off and wash it. Please see care label.
•
The area that can be cleaned with one pad will vary depending on the condition
of the surface being cleaned.
3.3 Easy-Click-Extension poles
•
The handheld unit can be used as a hand tool for easy to reach areas. (picture 5)
•
The hand held unit can be extended to reach higher or hard to reach surfaces
using the available short 63 cm or the longer 124 cm Easy-Click poles
(see page 4).
•
The system is designed to use a maximum of two long and one short extensi-
on. In case of maximum pole length it is recommended to use the short pole as
lowest section to get maximum stability. Never exceed maximum recommen-
ded length. Unger is not liable for any damages or injuries resulting from the
failure to follow these instructions.
•
The handle of the unit and the Easy-Click poles have a triangular profile. When
adding extension poles, be sure locking pins are locked into corresponding
pin holes. (picture 6)
•
To unlock, press the locking pin and separate the extension poles. (picture 7).
•
Be careful to not pinch your fingers in the swivel mechanism.