T1=Water inlet temperature /Tset= set temperature=28℃
NO
Condition
When the heat pump starts
1
When the heat pump is
running
When the heat pump starts
2
When the heat pump is
running
Current
Water inlet Temperature
working Status
Startup
T1≤27℃
Heating mode
T1≥29℃, last for 3 minutes
Standby
T1≥30℃
Cooling mode
T1=28℃, last for 3 minutes
Standby
T1≤27℃, last for 3 minutes
Startup
27℃<T1≤29℃
Heating mode
T1≥29℃, last for 3 minutes
Standby
T1≥30℃
Cooling mode
T1=28℃, last for 3 minutes
Standby
T1≤27℃, last for 3 minutes
Heating mode
Standby
It switches to cooling mode
Standby
It switches to heating mode
Heating mode
Standby
It switches to cooling mode
Standby
It switches to heating mode