3.7 Electrical connection

Note: Although the heat pump is electrically isolated from the rest of the swimming pool system, this only prevents
the flow of electrical current to, or from the water in the pool. Earthing is still required for protection against short-
circuits inside the unit. Always provide a good earth connection.
Before connecting the unit, verify that the supply voltage matches the operating voltage of the heat pump. It is
recommended to connect the heat pump to a circuit with its own fuse or circuit breaker and to use the appropriate
wiring.
Connect the electrical wires to the terminal block marked ' POWER SUPPLY '.
A second terminal block marked 'WATER PUMP ' is located next to the first one. The filter pump (max. 5 A / 240 V)
can be connected to the second terminal block here. This allows the filter pump operation to be controlled by the
heat pump.

3.8 Initial operation

Note: In order to heat the water in the pool (or hot tub), the filter pump must be running to cause the water to
circulate through the heat pump. The heat pump will not start up if the water is not circulating.
After all connections have been made and checked, carry out the following procedure:
(1) Switch on the filter pump. Check for leaks and verify that water is flowing from and to the swimming pool.
(2) Connect power to the heat pump and press the On/Off button
start up after the time delay.
(3) After a few minutes, check whether the air blowing out of the unit is cooler.
(4) When the filter pump is turned off, the unit should also turn off automatically, if not, then adjust the flow switch.
(5) Let the unit and the pool pump run 24 hours a day until the water reaches the desired temperature. On reaching
the chosen set temperature, the heat pump stops, when the pool temperature drops more than 2 ° C, the heat pump
restarts (if filtration is active).
Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take several
days to heat the water to the desired temperature. A good swimming pool cover can dramatically reduce the required
length of time.
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate. It will turn on when
the pool pump runs and shut it off when the pump shuts off. If the pool water level is higher than 1 m above or below
the heat pump's automatic adjustment knob, your dealer may need to adjust its initial start-up.
Time delay - The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive contact
wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will trigger this
time delay and prevent the unit from restarting immediately. Additional power interruptions during this delay period
do not affect the 3-minute duration of the delay.
3.9 Condensation
The air drawn into the heat pump is cooled by the operation of the heat pump to heat the pool water, which may
cause condensation on the fins of the evaporator. The amount of condensation may be as much as several litres per
hour at high relative humidity. This is sometimes mistakenly regarded as a water leak.
on the electronic control panel. The unit will
50