23 °C
SET TAMB
PROG - 1
As to PROG - 2, perform the same operations, changing activation times and days.
! IMPORTANT
SEASON MENU 12
With the "Season" function the thermo-stove can be activated exclusively for heating sanitary facilities ("SUMMER" season). The Summer
function cannot be activated if DIAGRAM 0 or DIAGRAM 2 is installed for a hydraulic system.
To enter this menu, follow the steps below starting from the main menu status:
1. Press and hold the P4 key for 2 seconds until the CLOCK SETTING MENU appears.
2. Press the P4 key eleven times: the display will THEN show SEASON MENU 12.
3. Access via the P6 key: the display shows the desired screen.
4. Scroll with P4 or P5 to set the desired option (season).
5. By confirming with the P6 key, you will automatically go back to SEASON MENU 12.
Description of symbols and display messages
Symbols
10:35
20°C
WORK
CLOCK
SYMBOL
1
2
3
4
5
6
7
8
9
10
11
! IMPORTANT
Model Rodi Steel Use and Maintenance Manual
WHEN THIS MODE IS USED, CHECK THAT AFTER ANY AUTOMATIC SHUT-OFF THE BRAZIER
IS ALWAYS WELL CLEANED SO AS TO ENSURE PROPER AUTOMATIC SWITCH-ON.
WATER TEMPERATURE
40°C
ROOM TEMPERATURE
THERMO-STOVE STATUS
AIR FAN
CHRONOTHERMOSTAT
RESISTANCE
EXTERNAL THERMOSTAT
PUMP
WINTER MODE
SUMMER MODE
THREE-WAY VALVE ON BOILER
THREE-WAY VALVE ON HEATING
BOILER CONTACT
BUFFER TANK CONTACT
WHEN A SEGMENT APPEARS ON THE DISPLAY NEAR ONE OF THE SYMBOLS LISTED
ABOVE, IT MEANS THAT THE FUNCTION ASSOCIATED WITH THE SYMBOL IS ACTIVE.
Use P4 and P5 to set the desired temperature.
Press P6 to confirm.
MEANING
Rev.2 31/07/2017
Page66
8
9
1
10:35
2
10 11
3
20°C
40°C
4
5
WORK
6
7