6" SINGLE PHASE MOTORS AND REQUIRED CONTROL BOXES

Motor
HP
kW Volts Phase
Order No.
6M051
5
3.7
6M071
7.5
5.5
6M101
10
7.5
6M151
15
11
➀ NEMA 3R control boxes will be replacing the current models.

6-10" THREE PHASE MOTORS

Motor
HP
kW
Order No.
6M058
5
3.7
6M052
5
3.7
6M054
5
3.7
6M078
7.5
5.5
6M072
7.5
5.5
6M074
7.5
5.5
6M108
10
7.5
6M102
10
7.5
6M104
10
7.5
6M158
15
11
6M152
15
11
6M154
15
11
6M208
20
15
6M202
20
15
6M204
20
15
6M258
25
18.5
6M252
25
18.5
6M254
25
18.5
6M308
30
22
6M302
30
22
6M304
30
22
6M404
40
30
66M504
50
37
86M504
50
37
86M604
60
45
8M754
75
55
8M1004
100
75
8M1254
125
90
8M1504
150
110
10M2004
200
150
5-30 HP, 3 Phase 230 and 460 Motors have adjustable voltage feature, change voltage plugs to convert from 230V to 460V
operation. Spare Change Plug Order No's are: PLUG-230V or PLUG-460V.
Motor Dia.
vs Flange Dia.
230
1
6" x 6"
Motor Dia.
Volts
Phase
vs Flange Dia.
200
230
460
200
230
460
200
230
460
200
230
3
460
200
230
460
200
230
460
200
230
460
460
460
460
460
460
3
460
460
460
460
10 "x 10"
Rated Input
S.F.
Amps Watts Amps Watts Amps
24
4987
36
7675
1.15
50
10135
72
15180
Rated Input
S.F.
Amps
17.5
15.0
7.5
25.4
22.0
11.0
33.3
29.0
14.5
47.4
6" x 6"
1.15
42.0
21.0
61.2
54.0
27.0
77.3
68.0
34.0
91.8
82.0
41.0
53.0
6" x 6"
70.0
65.0
8" x 6"
80.0
1.15
96.0
127.0
8" x 8"
160.0
195.0
235.0
Service Factor
L.R.
27.5
5735
124
41
8950
167
58
11830
202
85
18050
275
Service Factor
Watts
Amps
Watts
4910
19.5
5610
4857
17.0
5520
4857
8.5
5520
7180
28.5
8230
7127
26.0
8140
7127
13.0
8140
9360
37.2
10700
9407
33.0
10730
9407
16.5
10730
13700
53.5
15710
13700
46.0
15800
13700
23.0
15800
18040
69.5
20820
17930
60.0
20650
17930
30.0
20650
22740
87.5
26190
22470
76.0
25800
22470
37.0
25800
27000
104.0
31120
27130
94.0
31160
27130
47.0
31160
35530
60.0
41100
45210
79.0
52380
44360
73.0
51000
52850
90.0
60900
65900
109.0
76100
87600
145.0
101300
110800
180.0
126000
130700
220.0
152000
171100
270.0
198600
Control Box
Order No.
CB05MC (3R)
CB07MC (3R)
CB10MC (3R)
CB15MC (3R)
L.R.
Amps
124
110
55
158
144
72
236
208
104
347
320
160
431
392
196
578
530
265
674
610
305
340
465
435
510
650
795
980
1060
1260