7. Removing the LevMixer
®
LevMixer
| Palletank
Caution:
Ensure that electrical power remains con-
nected to the machine when mixing multiple
bags consecutively. If the power is shut off,
it is necessary to wait 25 minutes prior
charging the drive again (Refer to section
5.2.).
A. When mixing is complete, turn the RPM
Regulator to zero (0) and turn the drive
switch to the OFF position (See Fig. 40).
Figure 40.
®
drive unit from the Palletank
®
Jacketed for LevMixer
B. Firmly hold the LevMixer
dle and raise the LevMixer
to release the locking lever. Release the lock-
ing lever by pulling it toward the control box.
C. Carefully lower the rear wheels of the
drive unit to the floor and roll the LevMixer
drive unit on its rear wheels away from the
Palletank
®
for LevMixer
D. Press down on the LevMixer
handle just until the guide bearings are free
from the guide rails.
E. Pull the LevMixer
ther away from the Palletank
lower the front wheel to the ground.
F. The Palletank
another station. The LevMixer
remains ready for mixing.
®
for
®
®
drive unit han-
®
drive unit slightly
®
®
.
®
drive unit
®
drive unit slightly fur-
®
and carefully
®
can now be wheeled to
®
drive unit
8. Emptying the Flexel
®
LevMixer
The specifically designed protection cap
allows for mixing along with bag emptying
while avoiding hold-up volume for 100%
liquid recovery.
A. Prior to starting bag emptying:
A.1. If the bag 8" plug is opened, you can
leave the bag protection cap into the clamp
holder
A.2. If the bag 8" plug is closed, remove
the protection cap from the clamp holder
B. Take the bottom port tube, open the
connector protective outer-wrap using the
reversible cable tie on the dispensing line
and carry out the connection according to
the standard procedures that apply on the
site (See Fig. 41).
Figure 41.
C. Open the clamp. Drain the bag –
Gravity or peristaltic pumping can be used.
(See Fig. 42)
®
Bag for
15