Description; Field Of Application; Installation - Vimar Eikon 20446.N Manual Del Instalador

Cronotermostato de batería
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76

1. DESCRIPTION.

Electronic timer-thermostat for ON/OFF ambient temperature con-
trol (heating and air-conditioning), daily/weekly programming, class
I temperature control device (contribution 1%), input for remote
switching of phone dialler on/off, change-over relay output 5(2) A
250 V~, powered by batteries AA LR6 1 .5 V - 3 modules .

2. FIELD OF APPLICATION.

The appliance is designed to control room temperature by acting on
the control circuit of the burner or circulation pump (heating) or on
the control circuit of the air conditioner (air conditioning), ensuring an
ideal temperature, every day, throughout the week .
The large display shows the room temperature, day, time, system
operating status and the daily temperature profile set for the cur-
rent program .
20 - ENGLISH

3. INSTALLATION.

The appliance must be installed in flush or surface mounting boxes
with Eikon, Arké and Plana frames and plates at a height of 1 .5 m
off the floor in a suitable position for correctly detecting the ambient
temperature . It must not be installed in niches, behind doors and
curtains or in areas affected by sources of heat or atmospheric fac-
tors . In particular, it must not be installed on outer walls or in
association with appliances that generate heat (e.g. dimmers
or lamps).
It should be used in dry, dust-free places at a temperature between
0 °C and +40 °C .
Tabla de contenido
loading

Este manual también es adecuado para:

Arké 19446.mPlana 14446Eikon 20446Arke 19446

Tabla de contenido