Roll the blower unit 90° so that fan blade openings
5
are facing out the back of the oven.
Before Rolling
Back of
Oven
Locate the two "knockout" plates, on the rear oven
6
panel, near the top of the oven.
Using tin snips, carefully cut the web area from the
two holes side-by-side (that secure the knockouts to
the oven). Cut all four webs on both rear knockouts;
this will allow the ventilation fan airflow to exhaust
out the rear of the oven.
CAUTION:
7 Place the blower unit back into the opening.
AFTER: Fan Blade
End B
WARNING:
can cause injury or death. Do not pull or stretch
not pinched..
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of microwave.
Installation Instructions
After Rolling
Back of
Oven
Be sure to trim the sharp
Snip all 4 webs
on each knockout
panel and
remove the metal
knockouts for rear
airflow.
End A
Attach the exhaust adaptor to the rear of the oven
8
by sliding it into the guides at the top center of the
back of the oven.
Slide
exhaust
adaptor into
guides on
oven rear.
Push down securely until it is in the lower locking
tabs. Take care to assure the damper hinge
is installed so that it is at the top and that the
damper swings freely.
Close the blower plate so it is closed over the top
9
tab of the exhaust adapter. Secure with the screw
removed earlier.
Blower Plate
17
Exhaust Adaptor
Damper
(hinge side up)
Locking
Tabs
Screw
Exhaust Adaptor
Screw
Back of
Oven
Guides
Back of
Oven