You will find the illustrations referred to above in the pages 3 – 6 of these

instructions for use.

Scope of delivery

Tank [1], with pump [2], spray line [4] with shut-off valve [9], instructions for use [5], carrying
strap [6], spray lance [7], (Fig. 1)

Technical data

Type
Max. filling amount
Total contents
Max. spraying pressure
Max. operating temperature
Weight when empty
Material of tank
How device is carried
Technical residual quantity
Max. volume flow
Recoil force
Table 1
Assembly
1. Fasten the carrying strap(s) [6] on the tank [1]. (Figs. 2a + 2b)
2. Screw the spray line [4] tightly into the outlet port [10]. (Fig. 3).
+
Note the location of the spigot in order to be able to insert the lock.
3. Insert the lock [11]. (Fig. 3).
► The lock closes and the spray line is secured from unscrewing out of the tank.
4. Push the hose [4] onto the shut-off valve [9] and secure it with the cap nut. (Fig. 3)
5. Screw the spray lance [7] onto the shut-off valve [9] (Fig. 3).
Checks
Visual inspection: Are the tank [1], pump [2], spray line [4] with shut-off valve [9] and
spray lance [7] free of damage? (Figures 1, 15)
+
Pay special attention to the connections between the tank – spray line and the spray
line – shut-off valve and to the condition of the pump threading and spray line.
Pump up the empty device to 2 bar.
No leaks:
► The pressure must not decrease more than 0.5 bar within 30 minutes.
Pull the red button on the safety valve [12]. (Fig. 4).
Function:
► The pressure must dissipate.
+
Using the wheel lock [40] the lever on the shut-off valve [9] can be locked and unlo-
cked. Unintentional spraying is prevented after locking. (Fig. 15)
► If required, reset the wheel lock [40] and activate the shut-off valve [9]. (Fig. 15)
► The shut-off valve must open and close.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
3598P
6 l (1.58 gal)
9 l (2.4 gal)
6 bar (88 psi)
50 °C (104 °F)
4.5 kg
Stainless steel
Shoulder
0,03 l
0,78 l/min
< 5 N
16
ENGLISH
3618P
10 l (2.64 gal)
13 l (3.43 gal)
5.0 kg
Back