14
www.electrolux.com
Problem
The lamp does not work.
The lamp does not work.
The compressor operates
continually.
Water flows inside the re‐
frigerator.
Water flows on the floor.
The temperature in the ap‐
pliance is too low/too high.
Possible cause
The temperature in the
appliance is too high.
The lamp is in stand-by.
The lamp is defective.
Temperature is set incor‐
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The door is not closed
correctly.
The water drainage plug
is not correctly posi‐
tioned.
Food products are not
wrapped properly.
Temperature is set incor‐
rectly.
The water outlet is clog‐
ged.
Food products prevent
that water flows into the
water collector.
The melting water outlet
is not connected to the
evaporative tray above
the compressor.
The temperature regula‐
tor is not set correctly.
The door is not closed
correctly.
Solution
Contact a qualified electri‐
cian or contact the nearest
Authorised Service Centre.
Close and open the door.
Contact the nearest Author‐
ised Service Centre.
Refer to "Operation" chapter.
Wait some hours and then
check the temperature
again.
Refer to climate class chart
on the rating plate.
Allow food products to cool
to room temperature before
storing.
Refer to "Closing the door".
Position the water drainage
plug in the correct way.
Wrap the food products bet‐
ter.
Refer to "Operation" chapter.
Clean the water outlet.
Make sure that food prod‐
ucts do not touch the rear
plate.
Attach the melting water out‐
let to the evaporative tray.
Set a higher/lower tempera‐
ture.
Refer to "Closing the door".