Technical Specifications - Johnson Controls SEC99 Serie Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Repairs and Replacement
Do not attempt to repair a damaged SEC99 UltraCap
or UltraTube. Contact the nearest
Johnson Controls/Penn® representative to obtain a
replacement.
Table 1: SEC99 Series Dimensions and Physical Features Selection Matrix
Series First
Fitting Type and Internal
Letter
Capillary/Tube Diameter
SEC99
A
1/4 in. SAE Female Flare with a 0.06 in.
(1.5 mm) Internal Diameter Capillary
B
1/4 in. SAE Female Flare with a 0.2 in.
(5 mm) Internal Diameter Tube

Technical Specifications

Product
Fittings
Materials
Style
Shape
Capillary
Outside
Diameter
Inside
Ambient Operating Conditions
Maximum Working Pressure
Burst Pressure
Suggested Torque to Seal
Compliance
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these
specifications, consult Johnson Controls/PENN Application Engineering at 1-800-275-5676. Johnson Controls, Inc. shall not be liable for
damages resulting from misapplication or misuse of its products.
Controls Group
507 E. Michigan Street
P.O. Box 423
Milwaukee, WI 53201
SEC99A UltraCap Armored Capillary and SEC99B UltraTube Armored Tubing Installation Instructions
Second
Letter
A
B
C
D
E
F
SEC99A UltraCap /SEC99B UltraTube
SEC99A: Forged brass nut with copper stem
SEC99B: Silver-color plated forged brass nut with copper stem
1/4 in. SAE female flare connector with breakaway Schrader valve depressor
(depending on type selected)
Straight or 90 elbow
SEC99A 0.125 in. (3.1 mm), SEC99B 0.250 in. (6.3 mm)
SEC99A 0.06 in. (1.5 mm), SEC99B 0.2 in. (5 mm)
-50 to 300 F (-46 to 149 C), 95% RH
690 psig (4,757 kPa)
3,450 psig (23,786 kPa)
8 to 10 lb·ft (10.9 to 13.6 N·m)
UL Recognized: File SA9457, CCN SFCS2
UL Recognized for Canada: SA9457, CCN SFCS8
First Tube Angle and
Depressor
Straight, with Depressor
Straight, with Depressor
Straight, with Depressor
Straight, without Depressor 90 , without Depressor
Straight, without Depressor Straight, without Depressor
90 , without Depressor
www.johnsoncontrols.com
Second Tube Angle and
Depressor
Straight, without Depressor
90 , with Depressor
90 , without Depressor
90 , without Depressor
Published in U.S.A.
3
Tabla de contenido
loading

Este manual también es adecuado para:

Sec99aSec99b

Tabla de contenido