Zipper Maschinen ZI-RPE60 Manual De Instrucciones página 43

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
20
RECYCLING
Do not dispose of your machine in residual waste. Contact your local authorities for
information on available disposal options. If you buy a new vibratory plate or
equivalent from your dealer, he is obliged in certain countries to dispose of your old
machine properly.
21
TROUBLESHOOTING
Hot surfaces and rotating machine parts while the engine is running can cause
serious injury or even death. Always stop the machine before carrying out
troubleshooting work and secure it against unintentional restarting.
Fault
Motor does not start
Motor stops
Engine does not deliver
enough power:
Insufficient vibration
Machine does not move
freely
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-RPE60
ZI-RPE9043
W A R N I N G
Possible cause / remedy
Check O
/O
switch and make sure it is positioned to
N
FF
"O
".
N
Check fuel supply.
Check engine oil level (a sensor prevents starting if oil
level is too low).
Make sure that the spark plug ignition cable is
connected.
Check spark plug
Check carburettor and air filter and make sure they
are clean.
Check fuel supply.
Check that the fuel tap is open.
Check oil levels.
Check the condition of the air filter.
Check fuel supply.
Check that the fuel tap is open.
Check the condition of the air filter.
Check throttle position
Check whether the V-belt slips or is lost.
Check throttle position
Check the underside of the disc for buildup.