Normal Switch-Off; Maintenance And Servicing Plan; Table Of Measures; Changing The Exciter Oil - Zipper Maschinen ZI-RPE60 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44

16.4.2 Normal switch-off

1. Set the upper throttle lever to "minimum" and let the engine run idle for approx. 3
minutes at low engine speed.
2. Then set the engine ON/OFF switch (ignition switch) to the OFF position.
3. Close the fuel switch.
4. Wait until the engine has cooled down before storing the machine.
17
MAINTENANCE
Hot surfaces and rotating machine parts while the engine is running can cause
serious injury or even death. Always stop the machine before carrying out any
conversion, adjustment, cleaning or maintenance work and secure it against
unintentional restarting.

Maintenance and Servicing PLan

17.1.1 Table of Measures

What to do?
Check fuel level
Check engine oil level
Control of the operating elements
Check for damaged parts
Checking for loose or lost screws
Change engine oil
Check V-belt
Change exciter oil
Air filter cleaning
Spark plug test
The specified intervals refer to working under "normal" operating conditions. Depending on the
load, a change/exchange may also be necessary at an earlier point in time.

Changing the exciter oil

ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-RPE60
ZI-RPE9038
W A R N I N G
N O T I C E
Waste oils are toxic and must not be released into the
environment! Contact your local authorities for information on proper
disposal.
Frequency
before each start-up
before each start-up
before each start-up
before each start-up
before each start-up
first after 20 h, then every 100 h
every 50 h; replacement after 300 h or 1
year
every 200 h
every 50 h, replacement after 300 h or 1
year
every 100 h; replacement after 300 h or 1
year
MAINTENANCE
38
Tabla de contenido
loading

Este manual también es adecuado para:

Zi-rpe90912003923758 9912003923755 8

Tabla de contenido