If your outlet looks like this:
Then choose a 3-wire power supply cord with
ring or spade terminals and UL listed strain
relief. The 3-wire power supply cord, at least 4 ft
(1.22 m) long, must have three 10-gauge copper
wires and match a 3-wire receptacle of NEMA
Type 10-30R.
3-wire
receptacle
(10-30R)
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
Flexible armored cable or nonmetallic sheathed copper cable
■
(with ground wire), protected with flexible metallic conduit.
All current-carrying wires must be insulated.
10-gauge solid copper wire. (Do not use aluminum.)
■
At least 5 ft (1.52 m) long.
■
For a grounded, cord-connected washer/dryer:
This washer/dryer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This washer/dryer uses a cord having an
equipment-grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
For a permanently connected washer/dryer:
This washer/dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the washer/dryer.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the washer/dryer
is properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
8
ELECTRICAL REQUIREMENTS – 240 VOLT MODELS
(CANADA)
It is your responsibility
To contact a qualified electrical installer.
■
To be sure that the electrical connection is adequate and in
■
conformance with the Canadian Electrical Code, C22.1 – latest
edition and all local codes A copy of above codes standard
may be obtained from: Canadian Standards Association, 178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single-phase, 240 volt, 60 Hz.,
■
AC-only electrical supply on a separate 30-amp circuit, fused
on both sides of the line. A time-delay fuse or circuit breaker is
recommended. Connect to an individual branch circuit.
This dryer is equipped with a CSA
■
International Certified Power Cord
intended to be plugged into a
standard 14-30R wall receptacle.
The cord is 5 ft. (1.52 m) long.
Be sure wall receptacle is within
reach of laundry center's location.
If using a replacement power supply cord, it is recommended
■
that you use Power Supply Cord Replacement Part Number
9831317.
For further information, please reference service numbers
■
located on the back cover.
4-wire receptacle (14-30R)