Charger
Mains voltage (input)
Mains frequency
Charging voltage (output)
Rapid charging
Charging times for BP, BPS and BPC battery packs, approx.
1.5 Ah
2.6 Ah
3.1 Ah
5.2 Ah
6.2 Ah
Permitted charging temperature range
Temperature monitoring
Safety class
Chargers suitable
– for charging Festool Li-ion battery packs: BP,
BPS and BPC in the following voltage and current
classes:
10.8 V (3S1P)
1.3 Ah, 1.5 Ah
10.8 V (3S2P)
2.6 Ah, 3.0 Ah
14.4 V (4S1P)
1.3 Ah, 1.5 Ah
14.4 V (4S2P)
2.6 Ah, 3.0 Ah, 4.2 Ah, 5.2 Ah*'
18.0 V (5S1P)
1.3 Ah, 1.5 Ah, 2.6 Ah, 3.1 Ah*'
6
Technical data
TCL 6
120 V ~
60 Hz
10.8 - 18 V=
max. 6 A
26 min
46 min
33 min
45 min
53 min
-5 °C to +55 °C
by means of NTC resistance by means of NTC resistance
/II
Intended use
18.0 V (5S2P)
– For internal use only
* rapid charging battery packs
The user will be liable for damage due to improp-
er use.
SCA 8
120 V ~
60 Hz
10.8 - 18 V=
max. 8 A
26 min
46 min
33 min
33 min
40 min
-5 °C to +55 °C
/II
2.6 Ah, 3.0 Ah, 4.2 Ah, 5.2 Ah*,
6.2 Ah*
WARNING