Technical Data; Intended Use - Festool SCA 8 Manual De Instrucciones

Ocultar thumbs Ver también para SCA 8:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

user is encouraged to try to correct the interference
by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment
and receiver.
– Connect the equipment into an outlet on a circuit
different from that to which the receiver is con-
nected.
– Consult the dealer or an experienced radio/TV
technician for help.
Charger
Mains voltage (input)
Mains frequency
Charging voltage (output)
Rapid charging
Charging times for BP, BPS and BPC battery packs, approx.
1.5 Ah
2.6 Ah
3.1 Ah
5.2 Ah
6.2 Ah
Permitted charging temperature range
Temperature monitoring
Safety class
Chargers suitable
– for charging Festool Li-ion battery packs: BP,
BPS and BPC in the following voltage and current
classes:
10.8 V (3S1P)
1.3 Ah, 1.5 Ah
10.8 V (3S2P)
2.6 Ah, 3.0 Ah
14.4 V (4S1P)
1.3 Ah, 1.5 Ah
14.4 V (4S2P)
2.6 Ah, 3.0 Ah, 4.2 Ah, 5.2 Ah*'
18.0 V (5S1P)
1.3 Ah, 1.5 Ah, 2.6 Ah, 3.1 Ah*'
6

Technical data

TCL 6
120 V ~
60 Hz
10.8 - 18 V=
max. 6 A
26 min
46 min
33 min
45 min
53 min
-5 °C to +55 °C
by means of NTC resistance by means of NTC resistance
/II

Intended use

18.0 V (5S2P)
– For internal use only
* rapid charging battery packs
The user will be liable for damage due to improp-
er use.
SCA 8
120 V ~
60 Hz
10.8 - 18 V=
max. 8 A
26 min
46 min
33 min
33 min
40 min
-5 °C to +55 °C
/II
2.6 Ah, 3.0 Ah, 4.2 Ah, 5.2 Ah*,
6.2 Ah*
WARNING
Tabla de contenido
loading

Este manual también es adecuado para:

Tcl 6

Tabla de contenido