10.3. Check inhalation and exhalation membranes
Note!
Exchange the inhalation and exhalation membranes at least every 2
years.
Check inhalation membrane
■ Carefully detach inhalation membrane on the tap and check visually for
rips or other damage.
■ Carefully re-attach inhalation membrane behind the tap.
■ The inhaling membrane must lie evenly on the sealing surface inside.
■ Ensure that the inhalation membrane is not stuck to the valve seat.
Check exhalation membrane
■ Release mask cap from mask body.
■ Hold exhaling membrane at the edge and pull out.
■ Check valve seat for soiling and damage. Clean if necessary.
■ Press exhaling membrane into the valve seat until it engages in position
so that it lies smoothly and evenly.
■ Ensure that the exhalation membrane is not stuck to the valve seat.
10.4. Check rubber seal and head straps together with lower
straps
■ Check the rubber seal [11-1] of the half mask [11-4] for cracks or other
damage.
■ Check headbands [11-2] as well as lower bands [11-3] for cracks or
other damage.

11. Care and storage

Careful handling together with constant care of the product is necessary
to ensure that the half mask functions properly.

11.1. Cleaning and Disinfection

Note!
If used daily, the half mask should be disinfected once a week. If it is
stored in an area that is not airtight, it should be disinfected every six
months.
Use half mask respiratory protection cleaner for disinfecting (# 134965).