General Descriptions - Cebora POWER POD 150M Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
1.1 Wear dry insulating gloves. Do not touch electrode
with bare hand. Do not wear wet or damaged gloves.
1.2 Protect yourself from electric shock by insulating
yourself from work and ground.
1.3 Disconnect input plug or power before working on
machine.
2
Breathing welding fumes can be hazardous to your
health.
2.1 Keep your head out of fumes.
2.2 Use forced ventilation or local exhaust to remove
fumes.
2.3 Use ventilating fan to remove fumes.
3 Welding sparks can cause explosion or fire.
3.1 Keep flammable materials away from welding.
3.2 Welding sparks can cause fires. Have a fire extin-
guisher nearby and have a watchperson ready to use
it.
3.3 Do not weld on drums or any closed containers.
4
Arc rays can burn eyes and injure skin.
4.1 Wear hat and safety glasses. Use ear protection and
button shirt collar. Use welding helmet with correct
shade of filter. Wear complete body protection.
5
Become trained and read the instructions before
working on the machine or welding.
6
Do not remove or paint over (cover) label.

2 GENERAL DESCRIPTIONS

2.1 SPECIFICATIONS
This welding machine is a constant current generator built
using INVERTER technology, designed to weld with
covered electrodes and for TIG procedures, with contact
starting.
IT MUST NOT BE USED TO DEFROST PIPES, START
ENGINES AND CHARGE BATTERIES.
2.2
EXPLANATION OF THE TECHNICAL SPECIFI-
CATIONS LISTED ON THE MACHINE PLATE.
This machine is manufactured according to the following
international standards: IEC 60974.1 - IEC 60974.3 -IEC
60974.10 CL. A - IEC 61000-3-12 - IEC 61000-3-11 (see
note 2).
N°.
Serial number, which must be indicated on any
type of request regarding the welding machine.
Single-phase
frequency converter.
Drooping characteristic.
SMAW. Suitable for welding with covered electrodes.
TIG
Suitable for TIG welding.
U0.
Secondary open-circuit voltage
X.
Duty cycle percentage. % of 10 minutes during
which the welding machine may run at a
certaincurrent without overheating.
I2.
Welding current
U2.
Secondary voltage with current I2
U1.
Rated supply voltage .
1~ 50/60Hz
50- or 60-Hz single-phase power supply
I1 max. This is the maximum value of the absorbed
static
transformer-rectifier
current.
I1 eff.
This is the maximum value of the actual current
absorbed, considering the duty cycle.
IP23S Protection rating for the housing.
Grade 3 as the second digit means that this
equipment may be stored, but it is not suitable
for use outdoors in the rain, unless it is protected.
Suitable for hazardous environments.
S
Note:
1-
The machine has also been designed for use in
environments with a pollution rating of 1. (See IEC 60664).
2-
This equipment complies with IEC 61000-3-
11 provided that the maximum permissible system
impedance Zmax is less than or equal to 0,369 at the
interface point between the user's supply and the public
system. It is the responsibility of the installer or user of the
equipment to ensure, by consultation with the distribution
network operator if necessary, that the equipment is
connected only to a supply with maximum permissible
system impedance Zmax less than or equal to 0,369.
2.3 THERMAL PROTECTION
This equipment is protected by a thermostat. When
the thermostat is tripped, the machine stops delivering
current but the fan continues to run. The yellow led (B)
lights to indicate when it is tripped. Do not shut off the
welding machine until the led has gone off.
2.4 MOTOR-DRIVEN GENERATORS
These must have a power equal to or greater than 6KVA,
and must not deliver a voltage greater than 260V
3 INSTALLATION
This must be carried out by skilled personnel. All
connections must be carried out according to current
regulations, and in full observance of safety laws
(regulation CEI 26-36 - IEC/EN 60974-9).
• Make sure that the supply voltage matches the voltage
indicated on the specifications plate.
• When mounting a plug, make sure it has an adequate
capacity, and that the yellow/green conductor of the
power supply cable is connected to the earth pin.
3.1
DESCRIPTION OF THE EQUIPMET
A) Current adjustment.
B) Yellow led (see 2.3).
C) Power ON led.
D) Output terminal (-).
E) Output terminal (+).
F) Switch.
G) Mains cable.
7
Tabla de contenido
loading

Este manual también es adecuado para:

504Power rod 180 mPower rod 200 m

Tabla de contenido