Kiruna
English
truck that is suitable for moving the cabinet in question. It must have a nominal capacity
of at least 1,000 kg.
Always place the forks at the indicated points in order to avoid the risk of

overturning, and always completely insert the forks.
No unnecessary personnel should be present in the lifting area.

Balance the weight of the unit so as to ensure that the load remains in

equilibrium (Rif. 3)
DO NOT use transportation devices to lift:
with a capacity of less than 1,000 kg

with inappropriate characteristics or that have been affected by use

with non-standard or worn wires or cables

Transportation procedures that differ from that indicated are prohibited.

8. Storage

DO NOT store the units in uncovered areas where they are subject to weathering

and direct sunlight. Exposure to ultraviolet rays leads to permanent deformation of
the plastic materials and damages the unit's components.
The units must be stored in closed areas, at a temperature between -25°C and

+55°C and with relative humidity between 30% and 90%.
Before storing, check that the packaging is intact and that it doesn't show any

defects that could compromise the preservation of the units.

9. Receipt, unpacking, initial cleaning - qualified operator -

Before starting any unpacking operations, take all possible precautions to avoid injury
to the operator.
The unit may be provided packaged in one of the following ways:
With a wooden frame fixed to the base and a nylon covering held in place by straps

(standard) (Rif. 8);
With cardboard covering (upon request) (Rif. 9);

With a wooden cage (upon request) (Rif. 10).

Upon acceptance of the cabinet:
Ensure that the packaging is intact and there is no obvious damage;

Unpack, ensuring that the unit is not damaged;

Check that all parts of the unit are intact;

If any damage is found, immediately contact your supplier;

Slowly remove the protective film, taking care to not rip it, in order to avoid leaving

traces of glue. If this occurs anyway, they can be removed using appropriate
solvents.
Clean for the first time using neutral products. Dry with a soft cloth. Do not use any

abrasive substances or metal sponges;
For correct disposal of the packaging, note that it consists of: Wood - Polystyrene -
Polythene - PVC - Cardboard.
DO NOT use alcohol to clean the methacrylate parts (Plexiglas).

During the unpacking operations, do not leave packaging elements such as

nails, wood, staples, nylon, etc. lying around and tools used for the operation
such as pliers, scissors, and pincers should not be left in the work area, as
they could cause injury or wounds.
These items should be removed using appropriate methods and placed in the

relevant waste collection locations.

10.Installation and environmental conditions - specialised technician -

Any change to the installation described here must be authorised by ARNEG
Spa.
To guarantee that the technicians assigned to install the unit work safely, the use of
28