OVERVIEW
• Large capacity boiler (40 litres).
• Electrical panel incorporated.
• Three heat outputs.
Space heating energy efficiency class
Space heating energy efficiency (ηs)
Sound power level (LWA)
2. GETTING STARTED
- Check that all drains are closed.
- Open the filling tap until the hydrometer (7) shows 1 kg/cm
- Open and close all the purging valves as soon as the water flows.
- Set the thermostat control (11) to minimum and be sure that the pump works normally.
- Open the purging valves again if needed.
- Open the filling tap until the hydrometer (7) shows 1.5 kg/cm
- Connect the main switch (1), the thermostat control and the switch (3) to start the heater.
Input
kcal/h
24 kW
20.640
27 kW
23.220
30 kW
25.800
33 kW
28.380
36 kW
30.960
39 kW
33.540
42 kW
36.120
45 kW
38.700
48 kW
41.280
51 kW
43.860
54 kW
46.440
Voltage
Pipe size
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
3x400V+N~
1 1/4"
2
.
2
.
- 7 -
A: Output
B: Input
Weight
76 kg
76 kg
76 kg
76 kg
76 kg
76 kg
76 kg
76 kg
76 kg
76 kg
76 kg
D
%
37
dB
36