• T he minimum height of the sauna cabin must
be 1.75m (interior height)
• V entilation openings must be provided in every
sauna cabin. The ventilation opening must
be on the wall directly below the sauna stove
approx. 5-10 cm above floor level. The waste
air must be discharged through an opening
diagonally opposite the stove in the rear wall
between the top and bottom benches. The
ventilation openings must not be sealed. The
cabin light and its installation must have a
splash-proof design and be suitable for an
ambient temperature of 140°C. Therefore
only an approved sauna light with max. 40W
may be installed with the sauna stove.
Installation instructions
Important!
Do not use any floor coverings under the stove if they are
made of inflammable material such as wood, plastic, etc.
Ceramic tiles are ideal for use in a sauna.
The area under the stove may suffer discoloration, even on
non-flammable flooring or joint material.
No compensation will be paid for discoloration or damage to
flooring or the sauna walls.
The distance between the rear of the stove and the cabin wall
depends on the design (wall mounting).
Installing the sauna stove
• A ffix the feet on the rear wall of the stove the screws supplied
(4 screws M5 x 12).
• F asten the bottom panel to the inner sheath with 4 self-
tapping screws 3.9 x 9.5.
• A fter making the electrical connection of the mains cable,
close the cover on the terminal box again (with the spacer
on the outside).
• P osition the sauna stove in front of the air intake opening.
Secure the wall bracket to the wall of the cabin using
the wood screws supplied. Insert the stone grate (see
description entitled "Placing the sauna stones on the stone
grate", section entitled "Cleaning and care").
• F or the installation of the sauna stove ensure that the vertical
distance between the top of the sauna stove and the ceiling
of the sauna cabin is at least 110 cm and the horizontal
(lateral) distance between the stove and the wall of the
cabin is at least 7 cm. The distance between the bottom of
the stove and the floor depends on the design of the stove
(adjustable feet). However, it should be ensured that the
stove is not placed on a floor made of highly inflammable
material (wood, plastic flooring, etc.). Ideally ceramic tiles or
the like should be used in the sauna. The distance between
the rear wall of the stove and the wall of the cabin also
depends on the design (wall bracket).
• T he distance between the stove safety grille or the bench
and other inflammable materials from the oven must be at
least 7 cm. The height of the safety grille must be equal to
the height of the stove at the front.