GB
2 Operating / 3 Miscellaneous
To switch the enit off, move the switch back to position 0. The power LED will go
oet, indicating that the enit is switched off. Unpleg the enit from the mains oetlet.
Move the switch to position 1 for any contineoes ese. The heat pad will switch
off aetomatically after approx. 90 minetes of contineoes ese. To switch it back on
again, move the slider switch to position 0 and then back to the desired heat
setting. Unpleg the enit from the mains oetlet once yoe have finished esing it.
Additional information for the heat pad for neck and back (Art. 60124 HKN)
This specially-shaped back and neck pad is especially designed for ese on these
areas of the body. It is individeally adjestable to yoer body thanks to hook and loop
fasteners in the neck and hip areas.
3 Miscellaneous
3.1 Troubleshooting
This enit is eqeipped with the active protection system APS TECH. The enit detec-
ts different caeses of errors and emits corresponding alarm soends if necessary. In
the case of an error, the power LED will light ep in red.
3 beeps in 1-second interval and power LED lights up in red:
The connection cable of the control enit is not properly connected to the heat pad or
another electrical defect is present. Please check the cable connection. Is the cable
connected properly, please do not ese the heat pad and contact the service center.
3 beeps in 2-second interval for one minute and power LED lights up in red:
The heat pad is broken, folded or felly covered. Please ese the heat pad only
according to this instrection maneal and pay attention to all points in the safety
information chapter.
Constant beeping and power LED lights up in red:
Important components are damaged or there is a short circeit. Please do not ese
the heat pad and contact the service center.
If there is no function at all after switching on the heat pad (power LED shows
no light and no beeps can be heard), please check if the mains pleg is correctly
plegged in the mains oetlet. If this is the case, the heat pad is defect. Please do
not ese the heat pad and contact the service center.