SLV NAUTILUS MR16 Instrucciones De Servicio página 3

Luminaria exterior
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
ENGLISH
OPERATING MANUAL FOR
OUTDOOR LUMINAIRE
NAUTILUS MR16
Read this short manual carefully and keep it accessible for further
reference!
SAFETY MESSAGES
Disregard of the safety messages may lead to danger of life, burning or
fire!
• Installation, mounting or works on the electrical connection may only be
carried out by an approved electrician.
• Type Y attachement: If the external flexible cable or cord of this luminaire is
damaged, it shall be exclusively replaced by the manufacturer or a
qualified electrician.
• The product may not be modified or converted.
• Do not hang or fasten anything on the product, especially no decoration.
• Do not cover the product - provide free air circulation.
• The luminaire may only be operated with a complete and intact protection
glass.
• In case of a malfunction you may NOT touch the product or operate it
further. Disconnect the product from the power supply by an external
switch or by the fuse.
A malfunction exists when:
• visible damages appear.
• the product does not work properly (e.g. flickering).
• smoke, steam or crackling sounds appear.
• smell of burning is recognisable.
• an overheating is recognisable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by an
approved electrician!
• This product is not intended to be used by children. Ensure that children do
not suffer any harm e.g. by burns from hot surfaces or by electrical shock.
Additional safety messages are indicated by this symbol:
USE AS DIRECTED
This product serves exclusively lighting purposes and may:
• only be operated using a suitable conventional transformer, output:
12V~50-60Hz.
• only be installed according to safety class III (three).
• only be operated when firmly mounted on a stable, even and tilt-fixed
surface.
• only be operated on normally or not flammable surfaces.
• not be exposed to strong mechanical loads or to strong contamination.
OPERATION
High currents with low-voltage installations! Check all electrical
connections once in a while for a secure fit.
The distance between the light source and the illuminated surface must
0,5 m
be at least
. Pay special caution to easily inflammable objects (e.g.
curtains, fabrics, foliage, etc.).
MAINTENANCE AND CARE
Light source
Exchange the light source always before it reaches its lifespan, to avoid
personal injuries, or damages of the luminaire or other objects.
Disconnect the product from the power supply, before you exchange the
light source. Let the light source cool down before replacement.
Use only light sources that are suitable for the product. Suitable light
sources are indicated on the type label.
• Suitable light sources: CR-C51, GX5.3, 35W
• Replacing the light source
• Remove the cover.
• Remove the glass.
• Remove the used light source.
• Stick the new light source into the socket.
• Put the glass back on.
• Attach the cover.
• Check and clean the gasket after each opening of the luminaire. The bearing
surface of the gasket must be free of dirt. These measures ensure that the IP
class is maintained.
• Note the proper fit for the gasket. Tighten the screws in a cross-wise order, to
achieve an even pressure on the gasket.
Care
• The following enviromental influences may have unwanted effects on the
surface of the product:
• acid rain and sour soil, high salt content in the air
• cleaning agents, fertilizer especially in flowerbeds
• thawing salt, other chemical substances (e.g. herbicides)
Protect the product by adequate means to avoid unwanted changes of the
surface.
Disconnect the product from the power supply and let it cool down, before
you clean the product.
• Clean the product on a regular basis using a slightly moistened, soft and fluff-
free cloth. Please also note additional supplied notes on maintanance and
care.
STORAGE AND DISPOSAL
.
Storage
• The product must be stored in a dry and clean environment. Do not strain
the product mechanically during storage.
After a damp or soiling storage the product may only be installed after
checking its condition by an approved electrician.
Disposal (European Union)
• Do not dispose the product with the regular household waste! Products
marked with this sign must be disposed according to the directive (WEEE,
2012/19) on electrical and electronic devices at local collection points for such
devices!
INSTALLATION
(only by an approved electrician)
Preparing the low-voltage (12V) power supply: The transformer should be used
up to 80% of its capacity. The total watt power of the connected luminaires must
not exceed the power output of the transformer. The distance between luminaire
and transformer should be at least 20 cm. The conductor length between an
electronical transformer and a luminaire may not be longer than 2 metres
(Electromagnetic Emission). Note the manufacturer's information for the
transformer.
Switch off the mains or respectively the connection lead before doing any
works!
High currents with low-voltage installations! Use only heat resistant wires
and clamps to avoid danger of fire. Check all electrical connections for a
secure fit.
Use only parts, which are supplied with the product or are described as
accessories!
Inspect the product for loose parts inside the housing. When there are
loose parts inside the housing and these are not explicitly described the
product may not be installed or operated.
Use the supplied fastening material only when it is suited for the
installation background. If this is not the case use only fastening material
suiting the installation background.
Unpacking
• Carefully take the product out of the packaging removing any transport
safeguards.
• Before disposal of the packaging material make sure that all components
of the product are removed.
Installation place
• The product is solely suited for installation on the wall, ceiling and floor.
• Note the security advice on the distance to the illuminated surface in the
chapter OPERATION.
The product may only be utilized according to IP67.
Prepare the power supply lead according to valid rules for outdoor
installations.
Do not seal the product yourself, using additional silicon or another
sealant.
Installation steps (read completely before installation)
• Remove the cover.
• Remove the glass.
• Stick the light source into the socket.
• Assemble the fixture in reverse order. Pay attention that the gasket fits
properly. The bearing surface of the gasket must be free of dirt. Tighten the
screws on the shield in a cross-wise order, to achieve an even pressure on
the gasket.
• Fasten the luminaire to the installation place using properly dimensioned
fastening materials or use the ground spike.
• Electrical Connection
• Connect the product with the prepared 12V power supply.
Check if the product functions properly and is securely fixed!
art.-no. 229090 © 23.03.2016 SLV GmbH,
Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany,
Tel. +49 (0)2451 4833-0
Technical Details are subject to change.
Tabla de contenido
loading

Este manual también es adecuado para:

229090Nautilus

Tabla de contenido