description of unit / starting operation
3.5
TechNIcAl DATA
voltage
max. current consumption
power cord
max. operating pressure
volume flow at 12 mpa (120 bar) with water
max tip size
max. temperature of the coating material
max viscosity
Weight
Special high-pressure hose
6,35 mm, 15 m - 1/4" - 18 NPSM
Dimensions (l x W x h)
vibration
Spray gun does not exceed 2.5m/s
max sound pressure level
* Place of measurement: 1 m distance from unit and
1.60m above floor, 12 MPa (120 bar) operating pressure,
reverberant floor
3.6
TrANSporTATIoN IN vehIcle
Secure the unit with a suitable fastening.
10
220~240 VAC, 50/60 Hz
5.3 A
See page 82
207 bar (20.7 MPa)
1.62 l/min
0.021 inch – 0.53 mm
43°C
20.000 MPa·s
13.6 kg
441 x 324 x 415 mm
80 dB*
4
STArTINg operATIoN
4.1
hIgh-preSSure hoSe, SprAy guN AND
SepArATINg oIl
1. If equipped, screw the pressure gauge (1) to the coating
material outlet (Fig. 2, Item 2).
2. Screw the high-pressure hose (3) to the coating material
outlet (Fig. 2, Item 4).
3. Screw the spray gun (5) with the selected tip onto the
high-pressure hose.
4. Tighten the union nuts at the high-pressure hoses firmly
so that coating material does not leak.
1
4
3
2
5. Fill the oil cup with Piston Lube (Fig. 3). Do not use too
much Piston Lube, i.e. ensure that no Piston Lube drips
into the coating material container.
Piston Lube prevents increased wear and tear to
the packings.
Attention
Impact 400
2
5