Auxiliary controls on your Zoneline.
Auxiliary Controls—Terminal Connections
The auxiliary controls are located behind the
room cabinet beneath the access cover.
Remove the room cabinet. See the
1
To Remove the Room Cabinet section.
Remove the screw from the access cover.
2
To make wiring connections, insert the wires
3
into the bottom of the terminals and tighten
screws securely.
After all desired connections have been
4
made, replace the access cover and room
cabinet.
Central Desk Control
Motion Sensor (Obtained locally)
When connected, the wall mounted motion
sensor will detect motion in the room and
automatically set back the room temperature.
The door and motion sensors work together
to automatically set back the room temperature.
The appropriate dip switch must be enabled.
8
Motion Sensor
Door Sensor
External Fan
The owner is responsible for making all
connections and setting the appropriate
dip switches.
CAUTION:
Improper wiring may damage the Zoneline
electronics. No common busing is permitted.
Damage or erratic operation may result.
A separate wire pair must be run from each
separate controlling switch to each individual
Zoneline.
Motion Sensor
Common - Ground
White - Heater
Yellow - Compressor
Black - Solenoid
Green - High Speed Fan
Green - Low Speed Fan
Red - 24 V AC only