Assembly & Operating Instructions - SKF 729101/300MPA Instrucciones De Uso

Ocultar thumbs Ver también para 729101/300MPA:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
3. Assembly & operating instructions
If adapter block is to be used on a relatively
lat surface, put the telescopic steel pipe in
corresponding slot of adapter block. Lock it in
position with the quick action lock screw.
The adapter block can also easily be locked on the
top of a working bench by means of a standard
G-clamp. It can also be clamped in a vice.
A
A. Quick action locking screw
B. Adapter block
C. Telescopic steel pipe
Screw the oil injector on the adapter block until the
thread can be seen in the inside slot.
Screw the rectangular gauge adapter nipple into the
thread of the pressure gauge tightly, so that a good
seal is formed. Make sure the lat surfaces of the
nipple are aligned with the pressure gauge.
The use of a vice, with soft aluminium jaws, can
greatly simplify the mounting of the pressure gauge.
This nipple will remain on the gauge. There is no
need to remove the gauge from the nipple after
using the equipment.
B
C
A. Gauge adapter nipple
A
EN
7
Tabla de contenido
loading

Este manual también es adecuado para:

729101/400mpa

Tabla de contenido