When the oil reservoir (K) is to be charged, the
nozzle is immersed in oil and the piston retracted
by the handle. The oil will then be sucked into the
reservoir.
To allow any air to escape, point the nozzle upwards
and depress the valve ball slightly. Screw the
reservoir onto the injector, the ball is automatically
depressed and the valve opened.
Make a few strokes with the lever to displace any
air trapped in the injector body and then close the
release valve irmly.
If the valve is not tight enough then it can be dificult
to reach the maximum pressure.
N O T E : that the oil reservoir can be reilled
without releasing the pressure from the pump.
Figure 2
K
L
The kit is now fully assembled and ready for use.
Ensure that no air is trapped in the system, by
pumping until air-free oil is released from the end
of the high pressure pipe. Thread the swivel nipple,
on the high pressure pipe, in to the application. If
necessary, use any of the connection nipples that
are delivered with the set.