Push the gauge adapter nipple into the top slot of
the adapter block.
N O T E :
To avoid misalignment the O-ring has to be located
on the lat part of the gauge nipple.
The O-ring has no sealing function, it only helps in
aligning the components.
The following operation should be done carefully.
The illustration shows how the seal will be achieved.
Screw the high pressure pipe nipple into the back
of the adapter block, while gently moving the gauge
adapter nipple in order to secure the correct position
of the high pressure sealing area.
Then screw the oil injector into the block until it is
touching the gauge nipple. Gently loosen and tighten
the pipe and oil injector until the oil injector is in the
correct position, then tighten the high pressure pipe.
Make sure all parts are properly aligned. Failure in
doing so will prevent proper sealing and will cause
leakage. The component design helps achieve an
effective sealing with a moderate tightening torque.
8
EN
E
D
A. Gauge nipple O-ring 226402–2
B. Oil injector 226400 E
C. Gauge adapter nipple 226402–1
D. Adapter block 226402
E. High pressure pipe
A
B
C