5. Recommended mounting
and dismounting luid
SKF mounting luid
SKF LHMF 300/5 mounting luid is recommended
when mounting shrink-itted components with the
SKF oil injection method.
The mounting luid is recommended for use at a
temperature of 18... 25 °C (64... 77 °F).
The luid contains anti-corrosive additives.
SKF dismounting luid
SKF LHDF 900/5 dismounting luid is recommended
when dismounting shrinkitted components with the
SKF oil injection method.
The dismounting luid should be used at a
temperature of 18... 25 °C (64... 77 °F).
The luid contains anti-corrosive additives.
Due to the high viscosity of the luid it might be
necessary to operate the pump slowly.
Oil cleanliness requirements
Dirt and metal particles in the oil can cause wear of
the piston mating surfaces, leading to excessive oil
leakage and permanent damage.
The recommended oil cleanliness level should meet
or exceed ISO 4406:1999 20/18/15.
Using luids, other than oils or SKF mounting and
dismounting luids, can cause corrosion and/or
damage to the piston mating surfaces.
Do not mix luids or oils of different brands.
The contents of this publication are the copyright of the
publisher and may not be reproduced (even extracts) unless
prior written permission is granted. Every care has been
taken to ensure the accuracy of the information contained in
this publication but no liability can be accepted for any loss or
damage whether direct, indirect or consequential arising out of
the use of the information contained herein.
12 EN