Blue Tube Connection - Watts H2O-DWRO300 Manual De Instalación, Operación Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Step 2
- The small square black
foam gasket with a circle
cut out of the middle
must be applied to the
inside of the drain saddle.
Remove sticky tape
backing and stick to the
drain saddle as shown.
Step 3
- The drain saddle must
be installed at least 1 ½"
above the nut of the P-Trap
elbow or cross bar from the
garbage disposal to insure
proper drainage. Using the
1/4" drill bit, drill into the
drain pipe at best available
location as specified above,
for drain saddle installation.
Take extreme caution to
only drill through one side of
the drain pipe.
CAUTION
!
Do not over tighten the screws. It may crack the drain saddle.
Step 4
- Assemble the drain saddle around the drain pipe
and align drain saddle fitting opening with the hole
drilled in the previous step - you may use a small
screwdriver to feed through the drain saddle into the
drain pipe to aid with the alignment. Using a Phillips
screw driver tighten the drain saddle bolts evenly and
securely on both sides.
NOTICE
The black 3/8" drain tube must be as SHORT and STRAIGHT as
possible to the drain saddle, making a downward slope from faucet
to drain saddle to allow for proper drainage. This is a gravity fed
line and if there is any bend or dip in the tube, the rinse water will
not flow into the drain properly. Water may back up and come out
the air gap hole in the back of the faucet.
Step 5
- Measure the 3/8" black
tube from faucet to the
drain saddle on the drain
pipe and make a straight
cut to the correct length.
Step 6
- Connect the black tube to
the open quick connect
fitting on the drain saddle
by pushing the tube all the way to the tube stop.
Rear View of 3 stage Reverse
Osmosis System
A
BLUE TUBE-FAUCET
GAC
H2O-F17
Blue Tube Connection (From FAUCET To The
Reverse Osmosis (RO) Module)
Step 1
- Locate the 1/4" BLUE tube from the RO faucet.
Position the module as indicated in the "rear view"
picture. Insert the Blue Faucet tube into the 1/4"
quick connect fitting (position A) located behind the
GAC Filter head making sure the tube is pushed in all
the way to the tube stop.
See Diagram Above.
Red Tube Connection (From FAUCET To The
Reverse Osmosis (RO) Module)
Step 1
- Locate the 1/4" RED tube attached to the RO faucet.
Insert the end of the red tube into the 1/4" quick
connect fitting ( position B) located behind the RO
Membrane head making sure the tube is pushed in
all the way to the tube stop.
Page 9
MOUNTING HOLES
C
B
RO MEMBRANE
CARBON BLOCK
H2O-F16
H2O-F12
BLUE TUBE-TANK
D
GREEN TUBE-FEED
RED TUBE-DRAIN
Tabla de contenido
loading

Tabla de contenido