Operational Parameters
NOTICE
Installation must comply with state and local plumbing regulations.
NOTICE
System is intended to be installed using the cold water supply only.
Operating
Temperatures:
Operating Pressure:
pH Parameters:
Iron:
TDS
(Total Dissolved Solids)
Turbidity
Hardness
Hardness: Recommended hardness not to exceed 10 grains per
gallon, or 170 parts per million.
* System will operate with hardness over 10 grains but the
membrane life may be shortened. Addition of a water
softener may lengthen the membrane life.
Water Pressure: The operating water pressure in your home
should be tested over a 24 hour period to attain the maximum
pressure. If the incoming water pressure is above 100 psi then a
water pressure regulator is required. A booster pump is needed
for incoming water pressure under 35 psi.
WARNING
!
Copper Tube: Reverse Osmosis water should not be run through
copper tube as the purity of the water will leach copper causing
an undesired taste in water and pin holes may form in the tube.
Page 3
Maximum 100°F (37.8°C)
Minimum 40°F
Maximum 100 psi (690 kPa)
Minimum 35 psi
Maximum 11
Maximum 0.2 ppm
< 1800 ppm
< 5 NTU
Maximum 10 Grains
Per Gallon *
(4.4°C)
(341 kPa)
Minimum 2