3- W ire Connection : Pow er Cord
W A RN I N G
• T h e middle ( neutral or ground) w ire, w h ich
is w h ite, of a 3- w ire pow er cord or a 3- w ire
conduit h as to be connected to th e middle
post of th e main terminal block. T h e
remaining tw o w ires of th e pow er cord or
conduit h av e to be connected to th e outside
posts of t h e main terminal connection block .
Failure to do so can result in electrical shock,
severe personal inj ury or death.
I nstall th e pow er cord as follow s:
For power cord installations, hook the strain relief
over the power cord hole ( 1
of the oven. Insert the power cord through the strain
relief and tighten it.
Do not install th e pow er cord w ith out a strain
relief.
1
Remove the lower 3 screws from the terminal
block and retain them.
2
Insert the 3 screws through each power cord
terminal ring and into the lower terminals of
the terminal block. Make sure that the center
(neutral) wire, which is white, is connected to the
center lower position of the terminal block.
3
Tighten the 3 screws securely into the terminal
block. D o not remove the ground strap
connections.
3- w ire connection
Black White Red
Conduit
connection plate
If screws are not tightened securely, it can result in
electrical spark and severe personal inj ury or death.
/
) located below the rear
3
"
8
Terminal
block
4- W ire Connection : Pow er Cord
W A RN I N G
• O nly a 4- conductor pow er- supply cord
kit rated 12 0 / 2 40 v olts, 5 0 amperes and
marked for use w ith ranges w ith closed-
loop connectors or opened spade lugs w ith
upturned ends sh all be used.
T h e w h ite middle ( neutral) w ire of th e pow er
cord or 4- w ire conduit h as to be connected
to th e middle post of th e main terminal
block. T h e oth er tw o w ires of th e pow er
cord or conduit h av e to be connected to
th e outside posts of th e main terminal
connection block. T h e 4th ground w ire
( green) must be connected to th e frame of
th e range w ith th e ground screw . Failure
to do so can result in electrical shock, severe
personal inj ury or death.
I nstall th e pow er cord as follow s:
Do not install th e pow er cord w ith out a strain
relief.
1
Remove the lower 3 screws from the terminal
block and retain them.
2
Remove the ground screw and bend the end of
the ground strap up so the slot is over the hole
of the center screw removed in step 1 .
3
Insert the ground screw into the power cord
ground wire (green) terminal ring and secure it to
the range frame.
4
Insert the 3 screws through each power cord
terminal ring and into the lower terminals of the
terminal block. Make sure that the white center
(neutral) wire is connected to the center lower
position of the terminal block.
5
Tighten the 3 screws securely into the terminal
block. The center screw now attaches the bent
up ground strap to the block.
4- w ire connection
Black White Red
G round
screw
If screws are not tightened securely, it can result in
electrical spark and severe personal inj ury or death.
INSTALLATION
17
Terminal
block
G round
strap
Bend strap up
and attach
Conduit
connection plate