REMOTE ICE MACHIE REFRIGERAT
CHARGE
Each remote ice machine ships from
the factory with a refrigerant charge
appropriate for installation with line sets of
up to 50' (15 m). The serial tag on the ice
machine indicates the refrigerant charge.
Additional refrigerant may be required for
installations using line sets between 51'
and 100' (15.5-30 m) long. If additional
refrigerant is required, refer to the chart
below for the correct amount to be added.
Ice Machine
K1000
K1700
Important
EPA CERTIFIED TECHICIAS
If remote line set length is between 51'
and 100' (15.5 and 30 m), add additional
refrigerant to the nameplate charge. Refer
to the table below for the model being
worked on.
Tubing length: ____________________
Refrigerant added to nameplate: _____
New total refrigerant charge: ________
n
Potential Personal Injury Situation
The ice machine contains refrigerant
charge. Installation of the line sets must be
performed by a properly trained and EPA
certified refrigeration technician aware of
the dangers of dealing with refrigerant
charged equipment. "
Part Number: 000014142 Rev 02 5/17
Refrigerant to be
added for 51'-100'
Line Sets
2 lbs (907g)
2 lbs (907g)
Warning
General
Condensers must be mounted horizontally
with the fan motor on top with nothing
obstructing it. There must be at least a 16".
(41 cm) clearance from the bottom for air
intake. The front coupling panel and one
other panel (back or side) must also be
unobstructed.
Remote condenser installations consist of
vertical and horizontal line sets between
the ice machine and the condenser. When
combined, they must fit within approved
specifications. The following guidelines,
drawings and calculation methods must
be followed to verify a proper remote
condenser installation.
otice
The compressor warranty (including the
labor replacement warranty) will not apply
if the remote ice machine is not installed
according to specifications.
The warranty also will not apply if the
refrigeration system is modified with a
condenser, heat reclaim device, or other
parts or assemblies not manufactured by
us unless we specifically approved the
component in writing.
3
2
1
Routing Line Sets
Installation
DOWNWARD
HORIZONTAL
SPIRAL
DOWNWARD
HORIZONTAL
SPIRAL
2
3
1
19