Communication Settings; Command Format - Hitachi CP-X2520 Manual De Usuario

Tabla de contenido

Communication settings

1. Protocol
19200bps,8N1

2. Command format

Byte Number
Command
Action
<SET>Change setting to
desired value [(cL)(cH)]
by [(eL)(eH)].
<GET>Read projector
internal setup value [(bL)
(bH)] .
<INCREMENT>
Increment setup value
[(bL)(bH)] by 1.
<DECREMENT>
Decrement setup value
[(bL)(bH)] by 1.
<EXECUTE> Run a
command [(bL)(bH)].
[Header code], [Packet], [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 ~ 4.
[CRC ag]
For byte number
[Action]
Set functional code to byte number 7, 8.
<SET> = [01h, 00h], <GET> = [02h, 00h], <INCREMENT> = [04h, 00h]
<DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]
the
command table above.
Refer
to
[Type], [Setting code]
For byte number
("h" shows hexadecimal)
0
1
2
Header
code
Packet
L
H
BEh EFh
03h
5, 6,
RS-232C Communication command table
refer to
9 ∼ 12
RS-232C Communication command table
, refer to
RS-232C Communication (continued)
3
4
5
Header
Data
CRC
ag
size
L
L
H
(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
06h 00h
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
6
7
8
9
10
Data
Type
Action
L
L
H
H
H
11
12
Setting
code
L
H
.
.
9
Tabla de contenido
loading

Este manual también es adecuado para:

Cp-x3020

Tabla de contenido