A1.8 Specification for water to be treated
MiniDUE has been designed and created for the treatment of drinking water.
If the water to be treated is not potable please contact Acqua Brevetti 95 s.r.l. (tel. +39.(0)49.8973432, e-
The dosing of AcquaSIL 2/15
The P
O
concentration in water treated by MiniDUE is lower than 5 mg/l. This value refers to water having,
2
5
before being treated by MiniDUE, a concentration of P
MiniDUE cannot be used to treat water containing chemicals of any kind (e.g. acids, bases, solvents,
detergents, antifreezes, glycols, etc.).
A2 INSTRUCTIONS FOR PERIODIC MAINTENANCE
A2.1 Periodic maintenance
Perform periodically the following checks:
For checking AcquaSIL 2/15
®
As AcquaSIL 2/15
is consumed, the refill bag filling degree decreases, deflating, until it reaches the
crushing. Arrange to replace the refill bag.
Working check
For the proper working of the dosing pump make sure that the product is dosed and consumed regularly.
The level in the AcquaSIL 2/15
®
AcquaSIL 2/15
refill
Replace periodically the AcquaSIL 2/15
1. Rotate the empty refill
clockwise
4. Get a new AcquaSIL 2/15
bag; unscrew the cap by breaking
the plastic ferrule
A2.2 Inactivity
After long inactivity periods open a tap placed downstream of the device and let water flow for at least 3
minutes. If the water distribution line should be cleaned and sanitized MiniDUE should be cleaned and
sanitized as well. Cleaning and sanitization are part of the extraordinary maintenance and must be
performed by qualified personnel only.
A2.3 Periodic checks
It is advisable to make two inspections per year by an authorized technician to verify the proper operation of
the equipment.
MAN 115
MINIDUE - ENGLISH
®
in water increases its content of phosphorus.
®
consumption
®
refill should decrease proportionally with water treated.
®
refill. Follow the following instructions.
2. Unthread the empty refill
®
5. insert the new refill
refill
O
< 0.05 mg/l.
2
5
3. Dispose the empty refill in
accordance
regulation (the refill is made of
multilayered
material)
6. Thread the new refill
with
the
local
non
recyclable
PAG.E-5