F)
Audio
adjustments:
G)
MIC
Microphone connections (microphone is located in the interior panel profile).
H)
Panel connectors:
• Video terminals, (coaxial).
V: live
M: mesh
Ct: camera activation (11 Vdc)
• System connection terminals:
+, -: power sypply(18 Vdc).
L: data bus.
+12: 12 Vdc output
C, NO, NC: relay contacts (lock-release connection)
BS, -: entrance hall button.
SP, - : open-door sensor connection.
S: activation of the exchanger
I)
Amplifier version
Lock-Release Activation Time
ADVANCED PROGRAMMING: Lock-release timing
There are two programmable lock-release activation times:
- Lock-release time set from the residence.
- Lock-release time set from the exit button (connected to the 'BS' and '-' terminals).
Carry out the following steps:
1.- With the power supply disconnected, short circuit the 'Bs' and '-' (negative)
amplifier terminals (or ppress the exit button where one
2.- Maintaining the short-circuit induced above, connect the system's power supply (at
this point it will no longer be necessary to maintain the short circuit or hold down
the
button. A confirmation tone will sound once you enter programming mode.
3.- Following the confirmation tone, the lock-release time as currently programmed
from the residence will be indicated by way of a number of beeps at 0.5 second
intervals.
4.- Once these indicator tones have concluded, or before they conclude, press any button
on the panel, with one press for each second to be programmed (from 1 to 99 seconds).
To programme the lock-release time from the exit button, while in time programming
mode, (having finished programming the lock-release time from the residence or
following the indicator tones), wait 5 seconds before taking any other action.
Page 12
"door open"
exists).