Determine cable cross-section
I
NOTE
Keep the distance to the body battery as short as possible.
The minimum cable cross-section depends on the maximum cable length:
Cable length
to the starter battery
DCCxxxx-10
to battery structure
to the starter battery
DCC xxxx–20
to battery structure
to the starter battery
DCCxxxx-40
to battery structure
9.1
Connect charging converter
A
NOTICE!
The charging converter must not be connected directly to the alternator.
➤ Connect the charging converter as shown:
– Correct connection diagram: fig. 4, page 5
– Connecting the batteries: fig. 5, page 6
– Connect control line (I1): fig. 6, page 6
9.2
Connect accessories
I
NOTE - Performance regulation
To limit the output current of the charging converter to 5 A, a positive
control signal must be present at contact "I2" (fig. 1 5, page 3).
➤ Connect the accessory to the following contacts:
– Performance regulation (I2): fig. 1 5, page 3
– Temperature sensor: fig. 1 6, page 3
EN
Connect charging converter
Minimum cable cross-section/Fuse
2.5 mm² /
4 mm² /
30 A
40 A
 7 m
 11 m
 2 m
 3.5 m
 5.5 m
 1.5 m
6 mm² /
10 mm² /
60 A
80 A
 16 m
 5 m
 8 m
 14 m
 2.5 m
 4 m
 7 m
 2 m