Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1)
Pressing and holding the CAL
button for 2 seconds before
dispensing into a container will
cause the meter to skip a fill
operation and only change the
unit of measure.
IMPORTANT! For maximum
accuracy, try to get as close as
possible to the dispensed
volume without changing flow
rate.
1)
The left-most digit will begin
blinking.
2)
Use the TOTAL button to scroll from 0 to 9 until the desired number has been
selected.
3)
Press and release the CAL
button to move to the next digit.
4)
Repeat Steps 2 - 4 until the
amount of dispensed fluid has
been entered.
5)
If you make a mistake entering a
digit, press and release the CAL
button repeatedly until the digit
is active again.
6)
Press and hold the CAL button
for 2 seconds to complete the
calibration process regardless of
the current digit selected.
7)
If at the last digit and the CAL
button is pressed for less than 2 seconds, the process should roll back to the left-most
digit, but retain the current value. This allows the user to edit an incorrect value.
8)
An error check for gross calibration errors (+/- 15%) will be performed unless USER
units are selected. If an error is detected, the meter will display Err0 until a button is
pressed and the calibration process is aborted.
9)
If the meter is left untouched for 2 minutes or the RESET button is pressed, the unit
will automatically exit Calibration Mode and ignore any changes.

Operating Instructions

For accurate measurement and to
prevent meter damage, dispenser and
piping must always be filled with liquid
and be free of air. The meter portion of
your dispenser should be calibrated per
instructions in this manual prior to its
use.
The Fill-Rite 900 Series Digital Meter
face incorporates three buttons that
control all the operation and calibration
functions.
To turn the display on, or wake the
meter from "Sleep" mode, simply press
any button on the face. The display will
turn on and you can proceed with the
function you desire. Dispensing fluid will also turn the meter display on.
5
Tabla de contenido
loading