Control Panel Layout:
Control Panel Layout:
d
Once the salt level in the pool is correct the Unit may be switched On. (Note: Once the
unit starts there is a short time delay until the cell operates to ensure filtration
system is primed with water) At this point the Operation LED should be Green; if red
refer below. Note: Polarity LED may be either A or B (whichever is on or brightest).
The RED Operation LED will indicate a number of different possible problem situations:
Possible Problem
Salt Level Below Minimum
Cell is Calcified
Water temperature very cold
There is a problem with water flow
Page 9 of 18
Add Salt
Clean Cell
Add salt to compensate for cold water
Check pump / pipes for blockage or damage.
Check that flow sensor is connected properly
and in the right direction.
Action
P/N 403185