Tilt Mode Configuration; Datalogger Operating Mode - Promax PROPOWER - 5 Manual De Instrucciones

Analizador de espectros plc
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1.
Place the marker over the channel you want as low pilot.
2.
Press the SCAN key [11], and the message 'PILOT 1: PRESS TILT'
will appear at the bottom of the screen.
3.
Keeping the SCAN key [11] held down, press the TILT key [12], and a
message 'PILOT 1 ENTERED' will appear as confirmation.
Repeat the steps 1 to 3 for the 3 following pilots.
4.2.5.1

TILT mode configuration.

Pressing the CONFIG [14] key will
access to the first page of the configuration
menu.
To change a given parameter turn the rotary
selector [9] until the field is activated (this will appear
shadowed) and then press. The value of the
parameter will be activated and may be changed by turning the rotary selector. When
the value you want appears, press the rotary selector [9] to validate it.
a) PILOT 1
It defines a frequency belonging to the band (from 1 to 50 MHz) where the first
measurement of level will be done. This parameter, and the rest of pilots, is
defined digit by digit, by pressing repeatedly and turning the rotary selector.
b) PILOT 2
It defines the second pilot frequency belonging to the band.
c) PILOT 3
It defines the third pilot frequency belonging to the band.
d) PILOT 4
It defines the fourth pilot frequency belonging to the band.
To leave the configuration menu of the TILT mode, just press the key of the
operating mode you wish to access.

4.2.6 DATALOGGER operating mode.

The LOGGER function permits to automatically measure, the Carrier/Noise ratio
as well as the power channel measurements of each active channel in the channel plan
(see paragraph Channel Plan editor at section 4.2.1. Unit Global Configuration). These
measurements are stored in the memory so that they can be subsequently viewed,
printed or transferred to a PC. The PROPOWER-5 will store up to 55 obtained channels
or loggers in the memory, with a maximum of up to 140 analysed channels in each.
Page 26
USER'S MANUAL. PROPOWER-5
Figure 29.- TILT configuration.
IMPORTANT
07/2006
Tabla de contenido
loading

Tabla de contenido