Installation and Connections

When they leave the factory the chargers are
configured as follows :
Mains supply : 230Vac
Battery : Lead/Antimony
Charging mode : Boost ON, 3 step charging curve
Output voltage setting in Floating :
at 13.8 V ± 1% off load for 12 V models
at 27.4 V ± 1% off load for 24 V models
The battery cables must be connected to terminals.
1.5

REFERENCE STANDARDS APPLIED

The standards applied are :
NF EN 60950 + A1 + A2 (October 93) : safety of
information
processing
electrical office equipment.
NF EN 50081-1 (June 92) EMC : Generic standard
for emissions
NF EN 50082-1 (June 92) EMC : Generic standard
for immunity
NF EN 55022 (December 1994) : Limits and
methods for measuring the characteristics of RF
interference produced by information processing
equipment.
Enacted at Quimper on : 24 December 2002

2 Characteristics and operation

2.1

TECHNICAL CHARACTERISTICS

2.1.1 Mechanical characteristics

All models have an IP 22 protection rating. The
cover and clasp are made of steel and the base is
made of aluminium. These parts are protected by
several coats of epoxy paint.
Overall dimensions and weights of the various
models are specified in the table below :
Length
Model
(mm)
12V 06A
215
24V 03A
12V 10A
215
24V 05A
12V 12A
215
equipment
including
Height
Depth
Weight
(mm)
(mm)
(kg)
160
85
160
85
160
85
CPSDED

2.1.2 Input characteristics

Permissible input voltage (Vac) : 115Vac or 230Vac
+/- 15% single phase by manual selection.
Permissible input frequency (Hz) : 47 to 63 Hz.
Possibility to power the chargers from a generating
set (please refer to page 17).
Model
12V 06A
24V 03A
12V 10A
24V 05A
12V 12A

2.1.3 Output characteristics

2.1.3.1 Voltage
The output voltages shown in the table below are
obtained at 10% of rated power on outputs BAT 1
and BAT 2.
These values are set in the factory with an accuracy
of ± 1% and can be adjusted by turning the
potentiometer POT U (use a suitable tool for turning
the potentiometer screw).
They depend on the type of battery and mode of
operation selected.
Lead/Antimony
"Floating" Mode "
Lead/Antimony
"Boost" Mode
Lead/Calcium
Battery "Floating"
Lead/Calcium
1,6
"Boost" Mode
1,7
1,7
Typical
Typical
input
input
current
current
rating at
rating at
115Vac
230Vac
2A
1A
3A
1,5A
3,1A
1,6A
Model
Model
12 V
13,8 V
Battery
14,5 V
Battery
14,6 V
Mode
Battery
15,4 V
Page 14
Internal
input fuse
rating and
format
3,15A T 5x20
3,15A T 5x20
3,15A T 5x20
Model
24 V
27,4 V
28,8 V
29,0 V
30,5 V
Tabla de contenido
loading

Este manual también es adecuado para:

Cps 12v 06aCps 24v 03aCps 12v 10aCps 24v 05aCps 12v 12a

Tabla de contenido