Troubleshooting Table; Declaration Of Conformity - McCulloch M 320 Manual De Instrucciones

Tabla de contenido

TROUBLESHOOTING TABLE

WARNING:
recommended remedies below other than remedies that require operation of the unit.
TROUBLE
1.Engine flooded.
Engine will not
2.Fuel tank empty.
start.
3.Spark plug not firing.
4.Fuel not reaching carburetor.
5.Compression low.
1.Fuel not reaching carburetor.
Engine will not
idle properly.
2.Carburetor requires adjustment.
3.Crankshaft seals worn.
4.Compression low.
1.Air filter dirty.
Engine will not
2.Fuel not reaching carburetor.
accelerate,
lacks power, or
dies under a
3.Spark plug fouled.
load.
4.Spark arresting screen clogged.
5.Carburetor requires adjustment.
6.Carbon build up.
7.Compression low.
1.Choke partially on.
Engine
2.Fuel mixture incorrect.
smokes
excessively.
3.Air filter dirty.
4.Carburetor requires adjustment.
1.Fuel mixture incorrect.
Engine
2.Spark plug incorrect.
runs hot.
3.Carburetor requires adjustment.
4.Carbon build up.

DECLARATION OF CONFORMITY

EC Declaration of Conformity (Only applies to Europe)
We, Husqvarna AB, SE-561 82 Huskvarna, Sweden, tel: +46- -36- -146500, as authorised
representative in the Community, declare that the garden blower model McCulloch M 320
with serial numbers dating from 2009 and onwards (the year is clearly stated on the rating
plate, followed by the serial number), comply with the requirements of the COUNCIL'S
DIRECTIVES:
of 17 May 2006 "relating to machinery" 2006/42/EC;
of 15 December 2004 "relating to electromagnetic compatibility" 2004/108/EC, and applicable
supplements; and
of 8 May 2000 "relating to the noise emissions in the environment" in accordance with Annex
V of 2000/14/EC. For information relating to noise emissions, see Technical data section.
The following standards have been applied: EN ISO 12100-1/A1:2009, EN ISO
12100-2/A1:2009, CISPR 12:2007.
SMP Svensk Maskinprovning AB, Fyrisborgsgatan 3, S- -754 50 Uppsala, Sweden, has
performed voluntary type examination on behalf of Husqvarna AB. The certificate(s) are
numbered: SEC/09/2024.
09- -11- -01
Always stop unit and disconnect spark plug before performing any of the
CAUSE
REMEDY
1.See "Starting Instructions."
2.Fill tank with correct fuel mixture.
3.Install new spark plug.
4.Check for dirty fuel filter; replace.
Check for kinked or split fuel line;
repair or replace.
5.Contact an authorized service dealer.
1.Check for dirty fuel filter; replace.
Check for kinked or split fuel line;
repair or replace.
2.Contact an authorized service dealer.
3.Contact an authorized service dealer.
4.Contact an authorized service dealer.
1.Clean or replace air filter.
2.Check for dirty fuel filter; replace.
Check for kinked or split fuel line;
repair or replace.
3.Clean or replace spark plug; re-gap.
4.Replace screen.
5.Contact an authorized service dealer.
6.Contact an authorized service dealer.
7.Contact an authorized service dealer.
1.Adjust choke.
2.Empty fuel tank and refill with
correct fuel mixture.
3.Clean or replace air filter.
4.Contact an authorized service dealer.
1.See "Fueling Your Unit."
2.Replace with correct spark plug.
3.Contact an authorized service dealer.
4.Contact an authorized service dealer.